Product out of catalogue
fan image
Model
MBRL 1002 T4 75kW
Code
501610064

MBRL 1002 T4 75kW

MEDIUM PRESSURE WITH BACKWARD IMPELLER

MANUFACTURING FEATURES:

• Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average film thickness of 70 microns. Average heat resistence of coating is 180ºC with peaks of 200ºC.
• Fully welded or joined housing.
• Simple inlet backward impeller with self-cleaning system made of Fe360 sheet statically and dynamically balanced.
Impellers are painted with polyester primer that resists temperatures up to 300ºC.
• Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230/400V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.
• Standard orientation LG270.
• It allows adjusting the orientation locally from models 250 to 630. Models sizes from 710 to 1400 size the orientation is fixed.

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Industrial applications, extraction or injection of air.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air: 130ºC, ambient: 60ºC.

UNDER REQUEST:

• 60Hz fans and special voltages.
• 2 speed motors.
• Spark-proof fans with ATEX certified motor. 
• Fan for air working temperatures up to 250ºC with R/R (cooling impeller).
• Hot-dipped galvanised or stainless steel fans.
• Orientation: RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315, LG0, LG45, LG90, LG135, LG180. LG225, LG315.

Fan

Max flow
86410 m³/h
Weight
1278 Kg

Motor

Power
75 kW
RPM Motor
1485
I max. 400 V
133
I max. 690 V
77,1
Size
280M
Weight
639 Kg
Efficiency
95 %
FP
0.86
MBRL 1002 T4 75kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

MBRL 1002 T4 75kW

Dimensions scheme
A a a1 a2 B b b1 b2 C d D d1 D1 d2 D2 D3 D4 D5 D6 D7 E F G H H1 H2 I J K L M N N1xØ1 n1xp N2xØ2 n2xp O O6 Ø3 P R S S1 S2 S3 S4 S5 S6 S7 T U W X X1 X2 X3 X4 X5 X6 X7
360 1007 1077 1127 1635 715 785 835 1686 1007 710 1067 1171 1107 1015 976 936 815 718 1330 1995 607 358 950 710 1180 590 1056 1128 1255 690 716 24x14 3x200 18x14 4x200 100 620 20 1056 45 976 815 718 710 1330 1171 1015 936 67 1505 803 815 710 1330 1171 1015 976 936 718

MBRL 1002 T4 75kW

Electrical scheme

MBRL 1002 T4 75kW

Model
INT 25 3P A
Code
INT253PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
AC 1000
Code
960003220
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
JE 45
Code
300719201
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
RA 1007x24
Code
510010000
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
RI 1007x715
Code
510110000
Information
OUTLET PROTECTION GUARD FOR FANS

MANUFACTURING FRATURES

• Galvanized protection grid on the outlet side to avoid the entry of objects and contact with the impeller.

Model
EI 1007x715-1000
Code
510210000
Information
CIRCULAR OUTLET CONNECTION FLANGE

MANUFACTURING FEATURES

• Connection to be fitted in the centrifugal fans outlet.
• Manufactured in galvanized steel.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
INT 160 3P A
Code
INT1603PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
BIDS 715x1007-200
Code
BIDS-711007
Information
RECTANGULAR-RECTANGULAR ANTI-VIBRATION FLANGE FOR STORM

MANUFACTURING FEATURES

• Rectangular-rectangular coupling flange through anti-vibration canvas.
• Supplied with four L-shaped plates made of galvanized sheet metal and necessary screws.

MBRL 1002 T4 75kW

Spare parts scheme
Code Family Name Qty
2 T01610064 TURBINE MBRL 1002 T4 75kW LG x1
3 503410000SP04 INLET CONE NS/MTRL 1000 x1
4 721001401 MOTOR 75KW T4 B3 400/690V x1